Quality Ru-Ir Titanium Anode Plates & Assemblies for Wastewater factory
<
Quality Ru-Ir Titanium Anode Plates & Assemblies for Wastewater factory
Quality Ru-Ir Titanium Anode Plates & Assemblies for Wastewater factory
Quality Ru-Ir Titanium Anode Plates & Assemblies for Wastewater factory
Quality Ru-Ir Titanium Anode Plates & Assemblies for Wastewater factory
Quality Ru-Ir Titanium Anode Plates & Assemblies for Wastewater factory
>

Ru-Ir Titanium Anode Plates & Assemblies for Wastewater

Brand Name: Ti Time
Model Number: Custom to Drawing
Place of Origin: China
Minimum Order Quantity: To be confirmed by configuration
Price: Quoted per drawing and quantity

Product Details


Substrate: Titanium Plate Coating: Ru-Ir Mixed Metal Oxide (MMO)
Configuration: Single Plates Or Multi-plate Assemblies Plate Thickness: 0.5–5 Mm Or As Specified
Application: Electrochemical Wastewater Treatment

Product Description

Ru-Ir Coated Titanium Plate Anode for Industrial Wastewater Treatment

Ti Time supplies custom Ru-Ir coated titanium plate anodes, also known as ruthenium iridium coated titanium plate electrodes, RuO₂-IrO₂ titanium anodes or MMO titanium plate anodes, for industrial wastewater treatment, electrochemical oxidation, effluent treatment, water disinfection and advanced oxidation processes.

The anode uses titanium plate as the substrate and a ruthenium-iridium mixed metal oxide coating as the active catalytic layer. The titanium substrate provides corrosion resistance and mechanical strength, while the Ru-Ir MMO coating supports electrochemical oxidation, chlorine evolution and pollutant degradation under suitable working conditions.

Quick Summary
  • Ru-Ir MMO titanium plate anode for industrial wastewater treatment and electrochemical oxidation
  • Suitable for chloride-containing wastewater, disinfection, COD reduction support and hypochlorite generation
  • Flat plate, perforated plate, slotted plate, framed plate and custom electrode structures available
  • Coating formula, precious metal loading, plate size, terminal and service life design can be customized
Close-up of parallel titanium electrode plates and spacers

Key Features

Ru-Ir MMO Coating

Ruthenium-iridium oxide coating provides good electrochemical activity for chloride-containing wastewater, active chlorine generation and oxidation processes.

Titanium Plate Substrate

Titanium plate provides corrosion resistance, dimensional stability and mechanical support for industrial electrochemical equipment.

Custom Plate Structure

Flat plate, perforated plate, slotted plate, parallel plate assembly, framed electrode and non-standard structures can be customized.

Wastewater-Based Design

Coating loading, anode size and service life can be designed according to COD, chloride content, pH, conductivity and current density.

Product Specifications

Product Name Ru-Ir Coated Titanium Plate Anode for Industrial Wastewater Treatment
Other Names Ruthenium Iridium Coated Titanium Plate Electrode, MMO Titanium Plate Anode, RuO₂-IrO₂ Titanium Anode
Substrate Titanium Plate
Titanium Grade Gr1, Gr2, TA1, TA2 or customized titanium grade
Coating Type RuO₂ + IrO₂ mixed metal oxide coating
Optional Coating Ru-Ir, Ru-Ir-Ti, Ru-Ir-Sn or customized MMO coating
Precious Metal Loading 6–40 g/m² or customized according to working condition
Plate Thickness 0.5–5 mm or customized
Plate Structure Flat plate, perforated plate, slotted plate, parallel plate, framed plate or custom electrode
Connection Titanium handle, terminal, bolt, threaded rod, cable or customized connection
Applications Industrial wastewater treatment, electrochemical oxidation, effluent treatment, water disinfection and sodium hypochlorite generation

Suitable For

  • Industrial effluent treatment
  • Electrochemical oxidation reactors
  • High-COD wastewater treatment
  • Chloride-containing wastewater
  • Sodium hypochlorite generation
  • Water disinfection equipment
  • Pilot wastewater treatment systems

Coating Options for Wastewater Treatment

Different wastewater systems require different MMO coating formulas and precious metal loading. Coating selection should be based on chloride content, COD level, pH value, conductivity, operating temperature, current density and expected service life.

Coating Type Typical Feature Common Use
Ru-Ir Oxide Coating Good chlorine evolution activity and stable conductivity Chloride-containing wastewater, disinfection and hypochlorite generation
Ru-Ir-Ti Oxide Coating Balanced coating adhesion and practical stability General electrochemical oxidation and wastewater treatment systems
Ru-Ir-Sn Oxide Coating Designed for selected oxidation systems Organic wastewater and special electrochemical treatment projects
High-Loading Ru-Ir Coating Designed for longer service life under suitable conditions Continuous operation or higher current density systems
Custom MMO Coating Designed according to wastewater composition Project-based wastewater treatment equipment
Selection Note:

Please provide COD, chloride content, pH value, conductivity, temperature, flow rate, current density and expected service life before final coating selection.

Multi-plate titanium electrode assembly with insulating spacers

Flat plate, perforated plate, slotted plate, framed plate and parallel plate assemblies can be customized.

Titanium Plate Anode Structure Options

Ru-Ir coated titanium plate anodes can be designed according to wastewater reactor structure, liquid flow direction, electrode spacing, installation method and electrical connection requirements.

Flat titanium plate anode
Parallel plate electrode group
Perforated titanium plate anode
Slotted titanium plate anode
Framed titanium plate anode
Custom wastewater electrode

Applications in Industrial Wastewater Treatment

Ru-Ir coated titanium plate anodes are used in electrochemical wastewater treatment systems that require stable oxidation performance, controlled active chlorine generation, pollutant degradation, disinfection support and long-term electrode stability under suitable operating conditions.

Illustration of electrochemical oxidation and active chlorine generation in wastewater
Industrial Effluent Treatment

Electrochemical oxidation and pollutant degradation support for industrial wastewater systems.

High-COD Wastewater

Auxiliary oxidation process for difficult wastewater and advanced treatment projects.

Dyeing Wastewater

Color removal, oxidation treatment and disinfection assistance in dyeing wastewater systems.

Chemical Wastewater

Organic pollutant oxidation and microbial control support for chemical wastewater treatment.

Landfill Leachate

Electrochemical oxidation and pretreatment support for complex leachate wastewater.

Sodium Hypochlorite Generation

On-site active chlorine generation from brine or chloride-containing water.

How Ru-Ir Titanium Plate Anodes Work

In an electrochemical wastewater treatment system, the Ru-Ir coated titanium plate anode is connected to the positive pole of the DC power supply. When current passes through the wastewater or electrolyte, oxidation reactions occur on or near the anode surface.

Depending on the wastewater composition and electrolyte conditions, the system may support direct electrochemical oxidation, active chlorine generation, oxygen evolution, organic pollutant degradation, disinfection and odor reduction.

Reaction / Function Treatment Role
Direct electrochemical oxidation Oxidation of pollutants on or near the anode surface
Active chlorine generation Oxidation and disinfection in chloride-containing wastewater
Organic pollutant degradation COD reduction support under suitable operating conditions
Disinfection Microbial control through electrochemical oxidants
Diagram of a wastewater electrolysis cell with a Ru-Ir coated titanium plate anode

Custom Ru-Ir Coated Titanium Plate Anodes

Many wastewater treatment systems require non-standard plate sizes, special hole positions, slotted structures, different coating loadings or customized terminal designs. Ti Time can produce Ru-Ir coated titanium plate anodes according to drawings, samples or wastewater treatment conditions.

Custom Item Available Capability
Titanium Grade Gr1, Gr2, TA1, TA2 or customized titanium grade
Plate Thickness 0.5–5 mm or customized
Coating Type Ru-Ir, Ru-Ir-Ti, Ru-Ir-Sn or customized MMO coating
Precious Metal Loading 6–40 g/m² or customized according to current density and service life
Plate Shape Flat, perforated, slotted, framed or custom shape
Connection Method Handle, terminal, threaded rod, bolt, cable or customized connection
Electrode Assembly Single plate, parallel plate group or custom electrode module

Ru-Ir Titanium Plate Anode vs Other Wastewater Electrodes

Electrode selection should be based on wastewater chemistry, chloride level, oxidation target, current density, pH value, operating temperature and reactor design. Ru-Ir coated titanium plate anodes are often selected for chloride-containing wastewater, hypochlorite generation and practical electrochemical oxidation systems.

Item Ru-Ir Coated Titanium Plate Anode Ir-Ta Coated Titanium Anode Graphite Electrode Stainless Steel Electrode
Main Coating / Material RuO₂ + IrO₂ MMO coating IrO₂ + Ta₂O₅ MMO coating Graphite Stainless steel
Main Reaction Tendency Chlorine evolution / electrochemical oxidation Oxygen evolution / high-stability oxidation Conductive carbon electrode Sacrificial or conductive electrode depending on system
Typical Use Chloride wastewater, hypochlorite, disinfection and electro-oxidation Acidic systems, oxygen evolution and higher-stability oxidation Low-cost electrolysis or laboratory systems Electrocoagulation or simple electrode systems
Dimensional Stability Good under suitable conditions Good under suitable conditions Medium Medium to low in corrosive conditions

Quality Control & Export Packaging

Ti Time controls Ru-Ir coated titanium plate anode production from titanium plate selection to surface preparation, coating application, heat treatment, inspection and final packaging. Inspection items and documents can be arranged according to customer project requirements.

Inspection workstation and wooden crates for export packaging

Inspection & Packaging Support

Titanium plate inspection
Surface preparation checking
Coating loading control
Dimension and hole position check
Electrical continuity test
Protective export packaging

FAQ

Q1: What is a Ru-Ir coated titanium plate anode?

A Ru-Ir coated titanium plate anode is a titanium plate substrate coated with ruthenium-iridium mixed metal oxide. It is used as an insoluble anode in wastewater treatment, electrochemical oxidation and related electrolysis systems.

Q2: Why is Ru-Ir coating used for wastewater treatment?

Ru-Ir MMO coating provides good electrochemical activity and stable performance in suitable wastewater systems, especially in chloride-containing electrolytes where chlorine evolution and active chlorine generation may assist oxidation and disinfection.

Q3: Can Ru-Ir titanium plate anodes reduce COD?

Ru-Ir titanium plate anodes can support electrochemical oxidation processes that may help reduce COD under suitable wastewater conditions. Actual COD removal depends on wastewater composition, current density, chloride content, reaction time and reactor design.

Q4: What wastewater information is needed before quotation?

Please provide wastewater type, COD, chloride content, pH, conductivity, temperature, flow rate, target treatment result, operating current density, electrode size and reactor drawing if available.

Q5: Can Ti Time customize plate size and hole positions?

Yes. Ti Time can customize plate size, thickness, hole position, slot design, terminal, handle, frame and complete electrode assembly according to drawings.

Q6: What is the difference between Ru-Ir and Ir-Ta titanium anodes?

Ru-Ir coated titanium anodes are commonly selected for chlorine evolution and chloride-containing systems. Ir-Ta coated titanium anodes are more commonly selected for oxygen evolution, acidic systems and higher-stability oxidation conditions.

Q7: Can used Ru-Ir titanium anodes be recoated?

Yes. If the titanium substrate is still in good condition, used Ru-Ir MMO titanium plate anodes may be recoated after inspection.

Need Custom Ru-Ir Titanium Plate Anodes for Wastewater Treatment?

Send us your wastewater data, COD, chloride content, pH, conductivity, flow rate, current density, plate size, reactor drawing and expected service life. Our team will help confirm a suitable MMO titanium plate anode solution for your electrochemical wastewater treatment system.

Contact Ti Time for custom Ru-Ir coated titanium plate anodes for industrial wastewater treatment, electrochemical oxidation, sodium hypochlorite generation and water disinfection applications.

Product Highlights

Custom Ru-Ir MMO-coated titanium anode plates and multi-plate assemblies for electrochemical wastewater treatment. For quotation, send your drawing, wastewater type, chloride concentration and operating current density.

Related Products
Quality Coated Titanium Anodes for Electrolytic Copper Foil factory

Coated Titanium Anodes for Electrolytic Copper Foil

Coated titanium anodes for electrodeposited copper foil drum cells. For new or replacement anodes, send your drum dimensions, anode photos or drawing, mounting details and operating conditions.

Quality Ir-Ta Coated Titanium Anodes for Oxygen Evolution factory

Ir-Ta Coated Titanium Anodes for Oxygen Evolution

Custom iridium-tantalum MMO-coated titanium anodes for oxygen evolution and electrowinning. Send your drawing, electrolyte composition, pH, temperature and current density for quotation.

Quality Ru-Ir Titanium Anode Plates & Assemblies for Wastewater factory

Ru-Ir Titanium Anode Plates & Assemblies for Wastewater

Custom Ru-Ir MMO-coated titanium anode plates and multi-plate assemblies for electrochemical wastewater treatment. For quotation, send your drawing, wastewater type, chloride concentration and operating current density.

Quality MMO Tubular Anode String for ICCP Groundbeds factory

MMO Tubular Anode String for ICCP Groundbeds

Custom MMO-coated titanium tubular anode strings for deep-well and soil ICCP groundbeds. Specify tube dimensions, anode spacing, cable requirements, output current and target design life for quotation.

Request A Quote

Please use our online inquiry contact form below if you have any questions, our team will get back to you as soon as possible.

You can upload up to 5 files and Each file sized 10M max.