Quality Coated Titanium Anodes for Electrolytic Copper Foil factory
<
Quality Coated Titanium Anodes for Electrolytic Copper Foil factory
>

Coated Titanium Anodes for Electrolytic Copper Foil

Brand Name: Ti Time
Model Number: Custom to Drawing
Place of Origin: China
Price: Quoted per drawing and quantity

Product Details


Substrate: Titanium Application: Electrolytic Copper Foil Production
Dimensions And Mounting: According To Drawing Coating: Selected To Suit Operating Conditions

Product Description

Coated Titanium Anodes for Electrolytic Copper Foil

Ti Time supplies coated titanium anodes for the main deposition cells used to manufacture electrodeposited (ED) copper foil. For a new line or a replacement anode, we review the part geometry, mounting interfaces and coating requirements against your drum cell and operating conditions.

The anode faces the submerged portion of the rotating cathode drum. Its working profile must match the cell layout so the specified gap and electrolyte flow path can be maintained. For replacement projects, the interfaces and working profile are reviewed together with the coating.

Quick Summary
  • Coated titanium anodes for ED copper foil drum cells
  • New-line and replacement inquiries reviewed against drawings or existing samples
  • Curved or segmented profiles assessed against the drum and cell layout
  • Coating specification confirmed for the electrolyte and anodic reaction

Key Features

Drum Cell Fit

Review the anode profile, mounting datums and operating gap as a set, especially when a replacement must fit an existing carrier.

Defined Active Surface

Confirm which face and edges are coated and which mounting or electrical contact areas must stay uncoated.

Segment-by-Segment Review

Record the number, orientation and part identifiers of sections. Check whether left and right sections differ before ordering spares.

Replacement Support

If drawings are unavailable, start with measured photos, cell details and any existing anode identification.

Product Specifications

Substrate Titanium. Confirm grade and any material documentation on the order.
Coating Coating chemistry, active area and loading to be agreed against project requirements.
Cell duty Main deposition cell for electrodeposited copper foil.
Configuration Profile, curvature and segmentation according to the cell design and drawing.
Mounting Confirm hole pattern, slots, supports, datum surfaces and fastening details.
Electrical interface Confirm busbar contact face, terminal position and connection method.
Delivery scope Confirm bare anode sections versus a set with specified connection or mounting hardware.

How It Works in an ED Copper Foil Cell

Copper ions in the circulating electrolyte are reduced on the rotating cathode drum. As the drum emerges from the electrolyte, the deposited copper is peeled off as a continuous foil. The coated titanium anode supports the anodic reaction. Copper inventory is maintained through the line’s electrolyte supply system.

In curved drum cells, electrolyte flows through the gap between the anode and drum. Anode alignment, segment joints and the working gap are therefore useful checkpoints when diagnosing fit or uneven flow after a replacement. Foil quality also depends on cell and operating conditions.

Technical Parameters to Confirm

Drum geometry Outside diameter, face width, and usable deposition width.
Anode geometry Overall width and height, arc radius or profile, working face, and segment layout.
Working gap and flow Drawing value or measured gap, electrolyte inlet location and installation clearance.
Electrolyte Copper and free acid concentrations where available, additives, other relevant constituents, and operating temperature.
Electrical duty Operating current or current density, active area and duty cycle.
Acceptance Required tolerances, inspection documents and sample or trial requirements.

Customization Options

New Line or Pilot Cell

Send a drawing or section view of the drum and anode assembly, along with a parts list and required quantity.

Existing Line Replacement

Provide the existing part number, photos, drawing revision and installation constraints. Identify any geometry or connection changes requested.

Coating Review

Iridium-based mixed-metal-oxide coatings can be evaluated for acidic sulfate cells designed for anodic oxygen evolution. Confirm the existing coating and operating conditions before selection.

Typical Applications

  • Main deposition cells on ED copper foil lines serving PCB or battery applications
  • Replacement anode sections for existing rotating drum cells
  • Pilot-scale foil deposition equipment, subject to cell design review

Quality Control & Export Packaging

Agree the dimensional and documentation requirements before ordering. For replacement parts, the working profile, mounting pattern and electrical contact areas are the priority checks.

Dimensional Checks

Specify the drawing datums and measurements required for arc profile, overall size, holes and terminals.

Coating Documentation

Specify the active area and any requested coating inspection or documentation.

Packing Requirements

Confirm how the sections should be identified and supported, including protection for coated faces, edges and terminals in transit.

For Accurate Quotation

No drawing yet?

Send front, side and back photos of the old anode with a ruler in view. Include close-ups of the terminals and mounting holes, the overall size, quantity and known drum diameter. A measured arc radius or original part number helps identify which dimensions still need to be confirmed before production.

  • New installation or replacement and required quantity
  • Drawing or measured sample photos and drum dimensions
  • Electrolyte composition, temperature and operating current or current density
  • Existing coating designation and any inspection or packing requirements

FAQ

Does this page cover downstream foil surface treatment?

This product page focuses on the main foil deposition cell. For roughening or other surface-treatment stages, provide that stage’s electrolyte and operating conditions for a separate review.

Can I replace individual segments?

Send the segment identifier, joint layout and mounting details. We can review whether it can be quoted individually and what fit checks are needed.

Can you choose the coating from a photo?

Photos help identify the shape and connections. Share the existing coating specification if available, along with the electrolyte, temperature and current density, to review coating suitability.

Can you quote without a drawing?

Measured photos and the available cell data are enough to start a preliminary review. Confirm interfaces and required dimensions before production.

Need a Replacement Anode for an ED Copper Foil Line?

Send Ti Time your drawing or measured photos, drum dimensions, operating conditions and required quantity for a project quotation.

Product Highlights

Coated titanium anodes for electrodeposited copper foil drum cells. For new or replacement anodes, send your drum dimensions, anode photos or drawing, mounting details and operating conditions.

Related Products
Quality Coated Titanium Anodes for Electrolytic Copper Foil factory

Coated Titanium Anodes for Electrolytic Copper Foil

Coated titanium anodes for electrodeposited copper foil drum cells. For new or replacement anodes, send your drum dimensions, anode photos or drawing, mounting details and operating conditions.

Quality Ir-Ta Coated Titanium Anodes for Oxygen Evolution factory

Ir-Ta Coated Titanium Anodes for Oxygen Evolution

Custom iridium-tantalum MMO-coated titanium anodes for oxygen evolution and electrowinning. Send your drawing, electrolyte composition, pH, temperature and current density for quotation.

Quality Ru-Ir Titanium Anode Plates & Assemblies for Wastewater factory

Ru-Ir Titanium Anode Plates & Assemblies for Wastewater

Custom Ru-Ir MMO-coated titanium anode plates and multi-plate assemblies for electrochemical wastewater treatment. For quotation, send your drawing, wastewater type, chloride concentration and operating current density.

Quality MMO Tubular Anode String for ICCP Groundbeds factory

MMO Tubular Anode String for ICCP Groundbeds

Custom MMO-coated titanium tubular anode strings for deep-well and soil ICCP groundbeds. Specify tube dimensions, anode spacing, cable requirements, output current and target design life for quotation.

Request A Quote

Please use our online inquiry contact form below if you have any questions, our team will get back to you as soon as possible.

You can upload up to 5 files and Each file sized 10M max.