Coated Titanium Anodes for Electrolytic Copper Foil
Product Details
| Substrate: | Titanium | Application: | Electrolytic Copper Foil Production |
|---|---|---|---|
| Dimensions And Mounting: | According To Drawing | Coating: | Selected To Suit Operating Conditions |
Product Description
Coated Titanium Anodes for Electrolytic Copper Foil
Ti Time supplies coated titanium anodes for the main deposition cells used to manufacture electrodeposited (ED) copper foil. For a new line or a replacement anode, we review the part geometry, mounting interfaces and coating requirements against your drum cell and operating conditions.
The anode faces the submerged portion of the rotating cathode drum. Its working profile must match the cell layout so the specified gap and electrolyte flow path can be maintained. For replacement projects, the interfaces and working profile are reviewed together with the coating.
- Coated titanium anodes for ED copper foil drum cells
- New-line and replacement inquiries reviewed against drawings or existing samples
- Curved or segmented profiles assessed against the drum and cell layout
- Coating specification confirmed for the electrolyte and anodic reaction
Key Features
Review the anode profile, mounting datums and operating gap as a set, especially when a replacement must fit an existing carrier.
Confirm which face and edges are coated and which mounting or electrical contact areas must stay uncoated.
Record the number, orientation and part identifiers of sections. Check whether left and right sections differ before ordering spares.
If drawings are unavailable, start with measured photos, cell details and any existing anode identification.
Product Specifications
| Substrate | Titanium. Confirm grade and any material documentation on the order. |
|---|---|
| Coating | Coating chemistry, active area and loading to be agreed against project requirements. |
| Cell duty | Main deposition cell for electrodeposited copper foil. |
| Configuration | Profile, curvature and segmentation according to the cell design and drawing. |
| Mounting | Confirm hole pattern, slots, supports, datum surfaces and fastening details. |
| Electrical interface | Confirm busbar contact face, terminal position and connection method. |
| Delivery scope | Confirm bare anode sections versus a set with specified connection or mounting hardware. |
How It Works in an ED Copper Foil Cell
Copper ions in the circulating electrolyte are reduced on the rotating cathode drum. As the drum emerges from the electrolyte, the deposited copper is peeled off as a continuous foil. The coated titanium anode supports the anodic reaction. Copper inventory is maintained through the line’s electrolyte supply system.
In curved drum cells, electrolyte flows through the gap between the anode and drum. Anode alignment, segment joints and the working gap are therefore useful checkpoints when diagnosing fit or uneven flow after a replacement. Foil quality also depends on cell and operating conditions.
Technical Parameters to Confirm
| Drum geometry | Outside diameter, face width, and usable deposition width. |
|---|---|
| Anode geometry | Overall width and height, arc radius or profile, working face, and segment layout. |
| Working gap and flow | Drawing value or measured gap, electrolyte inlet location and installation clearance. |
| Electrolyte | Copper and free acid concentrations where available, additives, other relevant constituents, and operating temperature. |
| Electrical duty | Operating current or current density, active area and duty cycle. |
| Acceptance | Required tolerances, inspection documents and sample or trial requirements. |
Customization Options
Send a drawing or section view of the drum and anode assembly, along with a parts list and required quantity.
Provide the existing part number, photos, drawing revision and installation constraints. Identify any geometry or connection changes requested.
Iridium-based mixed-metal-oxide coatings can be evaluated for acidic sulfate cells designed for anodic oxygen evolution. Confirm the existing coating and operating conditions before selection.
Typical Applications
- Main deposition cells on ED copper foil lines serving PCB or battery applications
- Replacement anode sections for existing rotating drum cells
- Pilot-scale foil deposition equipment, subject to cell design review
Quality Control & Export Packaging
Agree the dimensional and documentation requirements before ordering. For replacement parts, the working profile, mounting pattern and electrical contact areas are the priority checks.
Specify the drawing datums and measurements required for arc profile, overall size, holes and terminals.
Specify the active area and any requested coating inspection or documentation.
Confirm how the sections should be identified and supported, including protection for coated faces, edges and terminals in transit.
For Accurate Quotation
Send front, side and back photos of the old anode with a ruler in view. Include close-ups of the terminals and mounting holes, the overall size, quantity and known drum diameter. A measured arc radius or original part number helps identify which dimensions still need to be confirmed before production.
- New installation or replacement and required quantity
- Drawing or measured sample photos and drum dimensions
- Electrolyte composition, temperature and operating current or current density
- Existing coating designation and any inspection or packing requirements
FAQ
This product page focuses on the main foil deposition cell. For roughening or other surface-treatment stages, provide that stage’s electrolyte and operating conditions for a separate review.
Send the segment identifier, joint layout and mounting details. We can review whether it can be quoted individually and what fit checks are needed.
Photos help identify the shape and connections. Share the existing coating specification if available, along with the electrolyte, temperature and current density, to review coating suitability.
Measured photos and the available cell data are enough to start a preliminary review. Confirm interfaces and required dimensions before production.
Send Ti Time your drawing or measured photos, drum dimensions, operating conditions and required quantity for a project quotation.
Product Highlights
Coated titanium anodes for electrodeposited copper foil drum cells. For new or replacement anodes, send your drum dimensions, anode photos or drawing, mounting details and operating conditions.
Coated Titanium Anodes for Electrolytic Copper Foil
Coated titanium anodes for electrodeposited copper foil drum cells. For new or replacement anodes, send your drum dimensions, anode photos or drawing, mounting details and operating conditions.
Ir-Ta Coated Titanium Anodes for Oxygen Evolution
Custom iridium-tantalum MMO-coated titanium anodes for oxygen evolution and electrowinning. Send your drawing, electrolyte composition, pH, temperature and current density for quotation.
Please use our online inquiry contact form below if you have any questions, our team will get back to you as soon as possible.